Useful And Essential Facts About Insulation Tester



By Barbara Morgan


In a perfect world, current that is sent along a conductive wire is supposed to reach the intended destination in full. However, this does not happen in the real world because some of the current is usually lost along the way. There are different reasons why the current gets lost along the way. In an attempt to prevent the loss of current, resistant sheathing is used to insulate conductive wires. Here are facts regarding Insulation tester.

In some cases, imperfections in cladding material allow current to leak and get lost to the surrounding. The leaking current can cause a lot of problems to the machinery and electrical circuits. That is why in order to maintain safety, the cladding needs to be tested on a regular basis. Doing this helps to identify problems before they cause equipment failure or harm people who handle the equipment through electrocution.

A cladding tester is the piece of equipment that is used to accomplish the testing. The equipment works by measuring the resistance of the cladding to flow of current. This indicates the integrity of the cladding in turn. Cladding that is of high quality allows very little current to escape through it. However, low-quality cladding allow huge amounts of current to escape through.

When measuring the quality of material used to make the sheath, different kinds of current are tested. Absorption, leakage and capacitive currents are the three main types of current tested. The current that occurs immediately when voltage is applied to conductors is referred to as capacitive current.

Capacitive current can be equated to the volume of water that comes out of a pipe immediately a tap is opened. Once the tap is opened, water usually flows out at a higher rate but as the pipe gets filled with water completely, the rate drops rapidly. For the case of a conductive material, the amount of current flow drops once the conductor becomes fully charged.

Absorption current is similar to capacitive current in that it starts out high but then drops. The only difference between these two kinds of currents is that absorption current drops at a much lower rate compared to capacitive current. The gradual drop in absorption current is due to the storage of potential energy in the cladding. Absorption current makes an important part of the time resistance method of cladding testing.

The third type of current tested is leakage current, which is also called conduction current. Unlike the other currents which drop over time, this type of current is small and steady. The current occurs both over and through the insulating sheath. Sheath that deteriorates in quality over time causes the leakage current to increase as time passes. The increase in leakage current as resistance decreases is indicated by an insulation test meter.

Currently, different types of cladding testers are available in the market. Different manufacturers from different countries produce these devices. The manufacturer of the equipment largely influences its quality. Different models of cladding testers are used to perform different functions. For instance, some testers are designed to perform testing in residential settings while other testers are meant to be used for testing equipment in industries.